Anche per Siemens SINUMERIK 840D sl: Istruzioni per l'aggiornamento (4 pagine), Istruzioni per l'aggiornamento (5 pagine), Manuale operativo (33 pagine), Manuale di messa in servizio (36 pagine), Istruzioni per l'aggiornamento (3 pagine), Istruzioni per l'aggiornamento (3 pagine), Manuale del sistema (44 pagine), Manuale dell'apparecchiatura (28 pagine), Manuale dell'apparecchiatura (26 pagine), Manuale dell'apparecchiatura (28 pagine)

Siemens SINUMERIK 840D sl Manuale dell'apparecchiatura
Calculation of the volume flow V:
V = 3.5 * PV
V = 17.5 [m
7.4

Standards and approvals

Approvals
CE approval
Figure 7-3
The operator panels and the safety-relevant accessories satisfy the requirements and
protection objectives of the following EC directives. The operator panels and the safety-
relevant accessories comply with the harmonized European standards (EN), promulgated in
the Official Journals of the European Community:
• 2004/108/EC "Electromagnetic Compatibility" (EMC directive)
• Directive 2006/42/EC of the European Parliament and Council of May 17, 2006, on
machinery, and Directive 95/16/EC (amendment)
China RoHS
The products comply with the China RoHS directive Further information on this can be
found on the Internet at the following link: SIOS
document/109738656/china-rohs-manufacturer?dti=0&lc=en-WW)
Risk assessment
The following standards must be used to perform the risk assessment:
• EN ISO 12100-1:2003 and EN ISO 12100-2:2003, General Design Guidelines for Machines
• EN ISO 14121-1:2007, Risk Assessment for Machinery
• EN ISO 13849-1:2008, Safety-related Parts of Machines
These considerations result in a category (B, 1, 2, 3, 4) and a performance level (PL a to e) in
accordance with EN ISO 13849-1:2008 that ultimately dictate how the safety-related parts of
the system to be monitored must be constructed.
The connection examples with different monitoring units in "Handheld units", Section: "HT 2",
Section: "Connections" → "Connection examples for acknowledgment button and Emergency
Stop button" can also be used for other operator panels and demonstrate how Category 3,
PL d according to EN ISO 13849-1:2008 can be attained with the safety-related parts of the
operator panels. Note that the overall concept of the installation must be designed with this
in mind.
Operator panel front: OP 010S
Equipment Manual, 12/2022, A5E50751046B AA
[W] / ΔT [K]
tot
/h]
3
CE marking
Technical specifications
7.4 Standards and approvals
(https://support.industry.siemens.com/cs/