Siemens SIWAREX WL270 CP-S SA Manuale di istruzioni per l'uso - Pagina 10

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Apparecchiature industriali Siemens SIWAREX WL270 CP-S SA. Siemens SIWAREX WL270 CP-S SA 38. Mounting plates cp-s sa
Anche per Siemens SIWAREX WL270 CP-S SA: Manuale di istruzioni per l'uso (40 pagine)

Siemens SIWAREX WL270 CP-S SA Manuale di istruzioni per l'uso
Description
3.1 Application
3.1.2

Lifting protection

The lifting protection prevents the load bearing implements from being lifted off of the load
cells.
If there is a risk of the load bearing implement being lifted or toppled, then lifting protection is
required. This is required in the case of lightweight containers and tall, outdoor silos.
3.1.3

Overload protection

The overload protection protects load cells from a load that is too great.
There is overload protection against excessive loads in the measuring direction and overload
protection against excessive transverse forces.
Transverse forces are caused by, for example, wind, filling processes, acceleration, or
conveyor belt friction. If these forces exceed certain values, the load cells must be protected
from them.
3.1.4

Use of the grounding cable

The grounding cable is used to protect the load cells from undesired currents. The causes of
such currents are, for example:
● Equalizing currents with missing or faulty equipotential bonding conductors.
● A lightning strike nearby
● Welding work
● Static charge
10
Figure 3-2
Example usage of the grounding cable
Operating Instructions, 04/2009, A5E02522341B
CP-S SA