Siemens FX-C Istruzioni per la riparazione - Pagina 16

Sfoglia online o scarica il pdf Istruzioni per la riparazione per Lavatrice Siemens FX-C. Siemens FX-C 34.

4.13

Water flow

Two-way detergent dispenser
The internal supply hoses of the prewash and main wash valves are
connected to the two-way detergent dispenser. If both valves are
actuated, the water jets hit each other and the water runs into the
middle fabric softener dispenser.
Continuous drain pipe
In these appliance the returned water tank has been omitted, and it
has been included in the drain pipe.
4.14

Drain Pump

4.14.1 Function:
The detergent-solution pump features a thermal protection device.
4.14.2 Technical specifications:
Nominal voltage
Frequency
Resistance
Delivery head
Delivery rate
209_58300000115677_ara_en_f.doc – 26.03.08
230–240
V
50
Hz
170 +/- 7% Ω
1.0
m
18
l/min
4.15

Pressure switch

The pressure switch has 2 levels:
Level I: Heating level. Aprox 26-36 mm from the bottom of the drum.
Level II: Safety level. Aprox. 470-530 mm from the floor.
Seite 16 von 34