20614 Cisco Installing and Maintaining Routers Part 4: 12000 GSR Series and XS5032 Modules
Router Card: Installing
Connect the switch to a computer or other data terminal equipment (DTE) device.
Connect the EIA−232 cable to the console, the DB−9 connector, on the switch.
Use the console configuration default settings for communication with the switch.
Power up the switch.
At the Greeting screen, press Return to enter the switch Main menu.
Press Ctrl and R from the switch Main menu to access the router card command−line interface (CLI).
Router Card: Configuring
Connect an auxiliary terminal to the auxiliary port on your switch.
Turn on the power switch.
The switch Greeting screen appears. To access the router card from the Main menu, you press Ctrl and R.
Select Configuration from the Main menu.
Select Router Configuration from the Configuration menu.
Enter the box and port numbers and press the Enter key.
Select the required option from the Router Configuration menu.
Catalyst 5000 RSM: Installation
RSM: Installing
Connect an ASCII terminal to a computer running terminal emulation software to the console port on the
Catalyst switch.
Use a screwdriver to loosen the captive installation screws and remove the module filler plate or the
existing module from the slot that you want to use.
Guide the RSM into the slot, aligning the sides of the RSM with the guides in the slot.
While keeping the module oriented horizontally, carefully slide it into the slot until its front panel makes
contact with the ejector levers.
Simultaneously push the left lever and the right lever in to fully seat the module in the backplane connector.
Tighten the captive installation screws on the left and right sides of the module.
Check the status of the module.
After verifying that the RSM is operational, enter the session mod/num command at the Cat5k>prompt.