Actulux HCV Series Manuale di istruzioni - Pagina 5
Sfoglia online o scarica il pdf Manuale di istruzioni per Azionamenti in corrente continua Actulux HCV Series. Actulux HCV Series 12. Chain drive
Connection for type HCVA in single mode
Caution!
The white and grey wire are only for changing parameters.
Parameter change can only be made by Actulux or an authorized service and sales partner
by Actulux.
Do not connect the white and grey wire to 230V!
Connection for type HCVAR in single mode
Caution!
The white and grey wire are only for changing parameters.
Parameter change can only be made by Actulux or an authorized service and sales partner
by Actulux.
Note! Do not connect the white and grey wires to 230V!
Do not use wired comfort switch for HCVAR. Use only wireless OPUS switch #111900
black
brown
blue
yellow/green
white
grey
black
brown
blue
yellow/green
white
grey
5
HCVA/HCVAR
L
N
PE
L N PE
230VAC / 50Hz
L
N
PE
L N PE
230VAC / 50Hz