ACETRAP
for compressed air system
USER GUIDE
Be sure to read the user guide before installation
and use.
The product warranty is included in the user guide.
youtube search : acetrap
https://youtu.be/VSvrPt3-zWM
-This manual is intended to protect users' safety and prevent property damage.-
Be sure to read it and use it correctly
1. Thank you very much for purchasing this product.
2. Please read this manual thoroughly before using the product and keep it in
an easy-to-find place.
3. In order to fully demonstrate the performance of this product, please observe
the operation method and precautions for use.
www.acetrap.com
Installation_
ACE Co.,Ltd
ATM C2000-08
Balance line
Inlet connection_
according to the level of the inlet, connect using a ball valve
and union as shown in the figure. The connecting inlet
should have a horizontal or downward sloping flow and
should not be angled upwards, such as on a camel, to
connect to the trap. This is because condensate does not
naturally flow into the trap.
Balance line_
(6-8 mm) to connect a balance line with the same pressure
as the inlet pressure. The balance line is usually taken from
a level above the level where the condensate collects
(mainly from the gauge if it is a tank).
If there is strong vibration (reciprocating
Caution
compressor) in the inlet line, use a flexible
hose, etc. to block the vibration.
receiver tank, etc.
Type A
Balance line
Inlet
Outlet
Dedicated
strainer
Caution
If the balance line is not
installed, condensate does
not flow into the trap due to
the air pocket
phenomenon.
1
It doesn't work.
Among the two inlets on the side,
Use a pneumatic hose or metal tube
(Air pocket
Tip :
1
https://acetrap.com/eng/acetrap/installation.html
Installation in places where it is difficult to
install a balance line_
Dryer, etc.
To facilitate the inflow of condensate in places where it is
difficult to connect the balance line, install Air Vent
In this case, use the lower of the two on the side of the
housing for the inlet, and install the air vent on the side of
the balance line on the top of the housing. Air vents are
optional and must be ordered separately.
Type B
Air vent
Dedicated
Inlet
strainer
The air vent should
always be slightly
opened, and it should be
checked frequently.
(If it is not opened, condensate will not enter the trap and
it will not work).
(Air vent
installation Tip :
2
https://acetrap.com/eng/acetrap/installation.html
Installation where the inlet descends
from above_
Filters, field lines, etc.
Type C
This installation method is used when
the inlet line goes from top to bottom
without bending. In this case, the
balance line is unnecessary, and you
can connect it directly to the top of
the housing entrance as shown in the
figure.
Caution
Always install traps
horizontally.
Do not install
upside down.
.
2