DigitaLinx DL-1H1V1U-WP-W Manuale d'uso - Pagina 13

Sfoglia online o scarica il pdf Manuale d'uso per Trasmettitore DigitaLinx DL-1H1V1U-WP-W. DigitaLinx DL-1H1V1U-WP-W 19.

CEC Setup and Control

A CEC enabled displays ON and OFF status can be controlled by the DL-1H1V1U-WP-W via HDMI from the DL-
HD2-RX by pressing the DISPLAY button on the DL-1H1V1U-WP-W. By default the CEC control option is always
on, simply turn the CEC option ON in the displays settings to use this control capability.
To turn the display ON using CEC, simply quick press the DISPLAY button on the DL-1H1V1U-WP-W; to turn
display OFF simply long press the DISPLAY button on the DL-1H1V1U-WP-W for 3-5 seconds.
CEC ON command can also be automatically generated to a connected display via HDMI when an active video
source is connected to the
delay commands to define the time when the display will be turned OFF when no video signals are present in
the DL-1H1V1U-WP-W.
For example if the delay time is set to 3 minutes, the CEC enabled display will turn off when there is no present
video signal in the switcher / extender for 3 minutes. By default the auto CEC control is on and the default
delay time is set to 3 minutes.
Use the commands below to adjust the settings for CEC control
Description
Auto CEC On/Off
Query Auto CEC Mode
Status
Reset Auto CEC Mode to
Factory Default
(Default is ON)
Set CEC Power OFF Delay
Time
Query CEC Power OFF Delay
Time
Reset Auto CEC Delay Time
to Factory Default
(Default is 3 minutes)
DL-1H1V1U-WP-W.
When using auto CEC on / off control of a display, use the CEC
Command
SET AUTOCEC_M {x}
{x} = [on, off]
GET AUTOCEC_M
RESET AUTOCEC_M
SET AUTOCEC_D {t}
{t} = [1-60]
Note: Maximum delay time is 60
minutes
GET AUTOCEC_D
RESET AUTOCEC_D
DL-1H1V1U-WP-W Owners Manual
Example
Command: SET AUTOCEC_M on<CR><LF>
Return: AUTOCEC_M on <CR><LF>
Command: GET AUTOCEC_M<CR><LF>
Return: AUTOCEC_M on <CR><LF>
Command: RESET AUTOCEC_M<CR><LF>
Return: AUTOCEC_M on <CR><LF>
Command: SET AUTOCEC_D 5<CR><LF>
Return:AUTOCEC_D 5 <CR><LF>
Command: GET AUTOCEC_D<CR><LF>
Return: AUTOCEC_D 5<CR><LF>
Command: RESET AUTOCEC_D<CR><LF>
Return: AUTOCEC_D 3 <CR><LF>
13