Argo CLIMIA CMK 4000 WiFi Manuale di istruzioni per l'uso - Pagina 18

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Condizionatore d'aria Argo CLIMIA CMK 4000 WiFi. Argo CLIMIA CMK 4000 WiFi 20. Room air conditioner with remote condenser

Room air conditioner with remote condenser
16 - TIPS FOR MAXIMUM COMFORT AND REDUCED CONSUMPTION
AVOID:
• Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged.
• Let direct sunlight into the room. Use sunshades, blind or curtain.
CHECK:
• Always try to keep the air filter clean. A clogged filter will impair the performance of the unit.
• To prevent conditioned air from escaping, keep windows, doors and any other openings closed.

17 - TROUBLESHOOTING

• The use of portable telephones near the air-conditioner may cause disturbance to its normal operation and must be avoided. In
case abnormal operation is noticed, (OPERATION lamp lights but outdoor unit will not run) to restore normal operation turn-off
electric supply for 60 seconds at least, by disconnecting the main switch or the wall plug, then start again the air-conditioner.
• The blinking OPERATION lamp, together with the stop of the air conditioner for a short time are due to the exceeding condensate
drainage. (see table "AUTO-DIAGNOSIS")
• If the OPERATION lamp goes on blinking and the air conditioner definitely stops means that the condensate pump is not working
or that the condensate drain pipe in the flexible connection pipe is obstructed; in this case contact the AFTER SALE SERVICE. In
case of emergency the air conditioner can work by draining the condensate from the back little pipe into a rather short container:
extract the little pipe and remove the cap.
• If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work
properly, contact your dealer or service center.
Trouble:
The air conditioner does not run at all.
Trouble:
Compressor runs but soon stops.
Trouble:
Poor cooling performance.
Trouble:
Clicking sound is heard from
the air conditioner.
CMK 4000
Possible cause:
1. Power failure.
2. Leakage breaker tripped.
3. Line voltage is too low.
4. Operation button is OFF.
5. Batteries in remote control unit
have run down.
Possible cause:
Obstruction in front of condenser coil.
Possible cause:
1. Dirty or clogged air filter.
2. Heat source or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge
port.
5. Thermostat is set too high.
Possible cause:
Any plastic parts may expand or shrink
due to a sudden temperature change.
In this event, a clicking sound may occur.
Remedy:
1. Restore power.
2. Contact service center.
3. Contact service center.
4. Press the button again.
5. Replace batteries.
Remedy:
Remove obstruction.
Remedy:
1. Clean air filter to improve airflow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat or cold out.
4. Remove it to ensure good airflow.
5. Set the temperature lower.
Remedy:
This is normal, and the sound will
disappear when an even
temperature is settled.
17