Argo CRONO Manuale di istruzioni per l'uso - Pagina 10

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Condizionatore d'aria Argo CRONO. Argo CRONO 16. Local

Argo CRONO Manuale di istruzioni per l'uso
1. COOLING MODE
 The "Cool" LED on the control panel will turn on.
 The temperature can be adjusted to between 16 °C and 31 °C.
 In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the temperature
setting and retains this setting when it is switched on again.
 In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set.
 For more silent operation, run the fan at low speed.
2. DEHUMIDIFICATION MODE (DRY)
Press the MODE button to select the dehumidification mode.
The temperature is controlled by the electronic board and cannot be adjusted.
In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the settings and
retains them when it is switched on again.
The fan speed is set to low and cannot be adjusted.
NOTE
The air conditioner does not cool the room when operating as a dehumidifier.
When the appliance is used as a dehumidifier, the flexible pipe must not be connected.
For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into
the environment.
The dehumidification mode is recommended during autumn and winter.
If used during summer, it is best to leave the flexible pipe attached so that the hot air is discharged towards
the outside rather than into the room.
During dehumidification, continuous drainage should be implemented (see the next chapter, "HOW TO ELIMINATE
CONDENSATE").
3. FAN MODE
Press the MODE button to select ventilation until the corresponding icon appears.
In this mode, the fan speed can be adjusted.
The temperature cannot be adjusted.
Manual drainage
V 12/19

OPERATING MODES

HOW TO ELIMINATE CONDENSATE
Cooling
This appliance automatically vaporises condensate in the cooling mode.
Ensure that when the unit is operating in cooling mode, the rubber caps
closing the drainage holes on the rear of the appliance are properly
positioned.
When the air conditioner operates in cooling mode, there is no need for
continuous condensate drainage; only in specific weather conditions with very
high air humidity levels may water deposit inside the unit. When the container
is full, the "Full" LED (full tank) lights up on the control panel to signal that full
status and block the appliance's operation.
To empty the container, switch the air conditioner off and unplug it. Remove
the cap form the rear drainage hole and direct it over a normal drain.
Ensure that the tube is not twisted or bent. The tube must slope downwards.
Re-close the drainage hole with the cap and resume use of the air conditioner.
26