Cisco TelePresence IX5000 Manuale - Pagina 19
Sfoglia online o scarica il pdf Manuale per Sistema di conferenze Cisco TelePresence IX5000. Cisco TelePresence IX5000 44. Field-replaceable units and countryand region-specific power connectors
Anche per Cisco TelePresence IX5000: Manuale d'uso rapido (15 pagine), Manuale d'uso (26 pagine), Manuale di installazione (36 pagine), Prima impostazione (40 pagine)
![Cisco TelePresence IX5000 Manuale](/uploads/products/server2/569464/569464.png)
Replacing a Left or Right Display
Step 1
Remove the bottom fascia by using the following procedure:
Note
While two people make this procedure easier, only one person is required.
a.
b.
c.
d.
Step 2
Power down the two PDUs mounted on the lower left and lower right display frames.
While wearing gloves, grasp the fascia from the left side at the top corner and pull it outward. Let
the fascia swing outward from its hinge.
Set the left side of the fascia on the ground, leaving it upright. Do not twist or put undue stress on
the joints.
Move to the center of the system, pull the center of the fascia outward, and set that part on the
ground.
Take the right end of the fascia at the upper corner, pull it outward, and set that on the ground.
Leave the center and side sections at slight angles so that it remains upright.
IX5000 Field-Replaceable Units and Country- and Region-Specific Power Connectors
Replacing a Display—Part Number CTS-5K-70-G1=
19