Cisco 3140 Manuale - Pagina 26

Sfoglia online o scarica il pdf Manuale per Hardware di rete Cisco 3140. Cisco 3140 42.
Anche per Cisco 3140: Come iniziare (42 pagine)

Cisco 3140 Manuale

Dual Fan Modules

Figure 12: Power Supply Module LEDs
1
For More Information
• See
Dual Fan Modules
The Secure Firewall 3100 has two fan modules that provide 3 + 1 redundancy. Each fan module has two fans
and each fan has two independent fan rotors. The fan rotors are monitored individually, and this gives 8 fan
rotors per system. When one fan rotor fails, all others spin at maximum speed so that the system continues to
function. The dual fan modules are hot-swappable and installed in the rear of the chassis.
The following figure shows the location of the fan LED on the fan module.
Overview
26
Amber FAIL LED
Fail LED Status:
• Off—No fault detected.
• Amber, flashing—Fault warning, power
supply may still work but could fail due to
high temperature, failing fan, or over current.
• Amber—Fault detected; power supply not
working properly. Includes over voltage,
over current, over temperature, and fan
failure.
Remove and Replace the Power Supply Module
power supply module in the Secure Firewall 3100.
2
Green OK LED
OK LED Status:
• Off—Input power not present.
• Green, flashing—Input power present, but
system is not powered up (power switch is
off).
• Green—The power supply module is enabled
and running.
for the procedure for removing and replacing the
Overview