Do not dry the filter with a heat source or with a hairdryer, it could catch fire. Use a vacuum cleaner with the lowest
possible power to avoid damaging the fibers. It is advisable to clean the filter every 3 months or more frequently,
depending on the frequency of use, for a maximum of 4 cleaning cycles, then it must be replaced.
STORAGE
If the dehumidifier will not be used for a long period of time, carry out the following checks before storing it: 1.
Remove the plug from the socket
2. Make sure that the water tank is empty and that the continuous condensate drain hose is disconnected.
3. Clean the appliance with a soft cloth from any dust deposits
4. Clean the filter
Store the appliance in a cool and dry place away from heat sources.
TROUBLESHOOTING
PROBLEM
The dehumidifier does not work.
Controls cannot be made.
Noise suddenly increases during
operation
Reduced dehumidification effect
V 07/20
POSSIBLE CAUSES
The temperature is above 32 ° C or below 5 ° C.
The internal tank is full.
The tank is not positioned correctly.
The plug is not connected correctly.
The compressor has just started.
Poer supply problem.
The unit is positioned on an uneven surface.
Ambient temperature is too low.
The filter is full of dust.
Doors and windows are open.
The entry and exit of the air are blocked.
If the unit operates with a temperature between
5 and 15 ° C, the unit will stop for automatic
defrosting. The compressor will stop for short
periods. After the defrost the unit will resume
normal operation.
There may be some appliance in the room that
emits steam.
The room temperature is too low
SOLUTION
Empty the tank
Position the tank correctly.
Connect the plug.
Place the unit on a regular and stable
surface.
Clean the filter.
Close doors and windows.
Remove objects that block the entry and
exit of the air.
This appliance should operate with a
minimum ambient temperature above 5
° C
28