Sony CDP-M11C Manuale di servizio - Pagina 2
Sfoglia online o scarica il pdf Manuale di servizio per Impianto stereo Sony CDP-M11C. Sony CDP-M11C 6. Compact disc player
Anche per Sony CDP-M11C: Manuale di servizio (6 pagine)
1-1. CONNECTION AND PREPARATION
Before entering the aging mode, connect as shown below, load a
writable disc (MD) into the HMD-M11 and set three discs (CD)
into the CDP-M11C.
optical cable
CDP-M11C
Compact Disc
Player
System control cable
(Attached to HMD-M11)
Note: The contents of disc are all erased, if a recorded disc is
used in the aging mode.
1-2. SETTING THE AGING MODE
With the power in OFF status, press =0 button and
VOL + button on the HMD-M11 simultaneously, and the aging
mode is activated.
Upper Bit
Hexa-
8
4
2
1
decimal
Bit
b7
b6
b5
b4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Decimal 0
0
0
0
0
0
0
1
0
0
1
0
0
1
0
0
1
0
0
0
All manuals and user guides at all-guides.com
SECTION 1
AGING MODE
HMD-M11
Mini-disc deck/
Tuner/Preamp
AC IN
Table 1-1. Description of Retry Cause Display
Lower Bit
Hexa-
Name of Retry
8
4
2
1
decimal
b3
b2
b1
b0
0
0
0
0
00
0
0
0
1
01
0
0
1
0
02
0
1
0
0
04
address error
1
0
0
0
08
0
0
0
0
10
0
0
0
0
20
0
0
0
0
40
0
0
0
0
80
cannot access
– 2 –
1-3. RELEASING THE AGING MODE
In the aging mode, press any button on HMD-M11, then press
POWER button on HMD-M11, and the power goes in OFF sta-
tus, then the set becomes ready for normal operation.
1-4. OPERATION IN AGING MODE
When the aging mode is activated, 4 cycle aging ↔ 10 minute CD
sync. dubbing are repeatedly executed until any button is pressed.
During a cycle aging, normal display is made (if an error occurs,
the operation stops with an error message kept displayed). Dur-
ing 10 minute CD sync. dubbing, MD retry count and a cause of
retry are displayed with a hexadecimal number, and also CD sound
skip count is displayed.
MD
CD
Sound skip count
Cause
(Not used)
(Not used)
shock
Track was skipped due to a shock
ADIP error
ADIP error occurred more than 5 times successively
ADIP addresses are not serial
Din unlock
Digital input is unlocked
focus
Focusing failed
IV-R
ABCD signal level exceeded the specified range
CLV unlock
CLV is unlocked (CLV is out of range)
Access failed
Retry count
Cause of retry
Description