DIGITEN DHTC-1011 Manuale di avvio rapido - Pagina 7

Sfoglia online o scarica il pdf Manuale di avvio rapido per Controllore DIGITEN DHTC-1011. DIGITEN DHTC-1011 8. Temperature and humidity controller

5. Press the
6. Long press the SET button to save and return to the home page.
7. Long press the SET button as Step 1.
8. Short press the
9. Press the
10. Short press the SET button to the SV value page.
11. Press the UP and DOWN button to set the SV to 50%.
12. Long press the SET button to save and exit.

Function introduction

CODE
RUN
STOP
HI
LO
DP
CA
Time of compressor delay starting(DP)
After power-on, in cooling mode, if PV ≥ STOP, the cooling device will
not start immediately and will wait for a delay time (DP).
When the time interval between two cooling operations is greater than
the delay time (DP), the cooling equipment will work immediately.
When the time interval between two cooling operations is less than
the delay time (DP), the cooling device will not start until it reaches the
delay time (DP).
When the cooling equipment stops instantaneously, the stop time will
be recorded as the time comparison point for the next start.
Calibration(CA)
When the PV(measuring temperature) deviates from the actual
temperature, it can be corrected with the temperature calibration
and
button to set the SV to 80°F.
or
button and SET button to select the Humidity.
and
button to set the RV to 40%.
Function
Temperature(Humidity)
Run Value
Temperature(Humidity)
Stop Value
H i g h t e m p e r a t u r e /
humidity alarm value
L o w t e m p e r a t u r e /
humidity alarm value
Time of compressor
Delay Starting
Temperature (Humidity)
Calibration
Setting range
120°C/40~248°F(0%RH-
99%RH)
- 4 0 ~ 1 2 0 ° C / 4 0 ~ 2 4 8 ° F
(0%RH-99%RH)
- 4 0 ~ 1 2 0 ° C / 4 0 ~ 2 4 8 ° F
(0%RH-99%RH)
- 4 0 ~ 1 2 0 ° C / 4 0 ~ 2 4 8 ° F
(0%RH-99%RH)
0~10minutes
- 1 5 ~ 1 5 ° C / - 1 5 ~ 1 5 ° F
(-10%RH-10%RH)
Defaults
20°C(40%RH)
40°C(80%RH)
120°C(99%RH)
-40°C(5%RH)
0minutes
0°C(0%RH)