Sfoglia online o scarica il pdf Manuale di avvio rapido per Hardware di rete Cisco S170 Web. Cisco S170 Web 25. Web security appliance

13

Configuration Summary

Item
Management
Data
Description
You can manage the web security appliance
from the management port (MGMT port)
by entering http://192.168.42.42:8080
or by using the IP address assigned to the
management interface after you have
completed the System Setup Wizard.
If you reset your configuration to factory
default settings (for example, by re-running
the System Setup Wizard), you can access
the management interface only from the
MGMT port (http://192.168.42.42:8080),
so ensure that you have a connection to the
MGMT port.
Also, verify that you open firewall ports 80
and 443 on your management interface.
After running the System Setup Wizard, at
least one port on the appliance is configured
to receive web traffic from the clients on the
network: M1 only; M1 and P1;
M1, P1 and P2; P1 only; or P1 and P2.
If you configured the web proxy in
Note
explicit forward mode, the
applications on the client machines
must be configured to explicitly
forward web traffic to the web
security appliance's web proxy
using the IP address configured for
data, either M1 or P1.