IO Throttle Count

Description: The total number of I/O requests that can be outstanding on a per-vHBA basis .
Parameter name: I/O Throttle Count
Parameter values:
Note: Prior to the UCSM 2 .1 .2a release, Cisco UCSM displayed an I/O Throttle Count parameter in the non-standalone Linux
and ESX Adapter Policies, and in the standalone Cisco Integrated Management Controller vHBA Properties field . This parameter
was programmatically ignored; modifying it had no effect on the actual adapter setting, which remained statically set . As of the
Cisco UCSM 2 .1 .2a release, this value is now honored .
Note: Some values' actual parameter settings are different than what is displayed in the UCSM and Cisco Integrated
Management Controller (IMC) GUIs . These differences are implemented to support backward compatibility and forward
consistency .
UCSM GUI / CIMC GUI configurable range = 1 to 1024
UCSM GUI default (non-standalone) = 16 displayed / 2048 actual parameter setting
CIMC GUI default (standalone) = 512 displayed / 512 actual parameter setting
UCSM GUI / CIMC GUI < 256 displayed / 256 actual parameter setting
UCSM GUI / CIMC GUI = 16 displayed / 2048 actual parameter setting
Configuration capabilities: Boot time only .