Cisco AS5300 - Universal Access Server Manuale di configurazione - Pagina 13

Sfoglia online o scarica il pdf Manuale di configurazione per Server Cisco AS5300 - Universal Access Server. Cisco AS5300 - Universal Access Server 46. Access server
Anche per Cisco AS5300 - Universal Access Server: Appendice (10 pagine), Manuale di avvio rapido (25 pagine), Manuale (21 pagine)

Cisco AS5300 - Universal Access Server Manuale di configurazione
Chapter 2
Configuring the Cisco AS5300 Network Access Server
Enter the show controller t1 number command to view the statistics for a particular T1 controller.
Step 2
If counters are increasing on a specific T1 controller, see the error statistics. Error counters are recorded
for a 24-hour period in 15-minute intervals. You must specify a specific controller number to see this
detailed information. Focus on the current interval.
In the following example, note that the frame loss and line errors present in data intervals 1 through 4
cleared in the current data interval.
Note
Receiver has loss of signal.
Version info of slot 0:
Manufacture Cookie Info:
EEPROM Type 0x0001, EEPROM Version 0x01, Board ID 0x42,
Board Hardware Version 1.0, Item Number 73-2217-4,
Board Revision A0, Serial Number 07557185,
PLD/ISP Version 0.0, Manufacture Date 17-Dec-1997.
Framing is ESF, Line Code is B8ZS, Clock Source is Line Secondary 3.
Data in current interval (142 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 142 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 142 Unavail Secs
Total Data (last 24 hours)
12 Line Code Violations, 0 Path Code Violations,
0 Slip Secs, 86400 Fr Loss Secs, 8 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 86400 Unavail Secs
Errors are reported to the controller's counters each time there is an error.
Therefore, clear the counters by using the clear controller t1 number command
before you look for current error statistics. Error counters stop increasing when
the controller is configured correctly.
hq-sanjose# show controller t1 0
T1 0 is up.
No alarms detected.
Version info of slot 0:
Manufacture Cookie Info:
EEPROM Type 0x0001, EEPROM Version 0x01, Board ID 0x42,
Board Hardware Version 1.0, Item Number 73-2217-4,
Board Revision A0, Serial Number 07557185,
PLD/ISP Version 0.0, Manufacture Date 17-Dec-1997.
Framing is ESF, Line Code is B8ZS, Clock Source is Line Primary.
Data in current interval (72 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in Interval 1:
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 405 Fr Loss Secs, 14 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 405 Unavail Secs
Data in Interval 2:
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 450 Fr Loss Secs, 1 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 450 Unavail Secs
Data in Interval 3:
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 450 Fr Loss Secs, 1 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 450 Unavail Secs
-------------------------------- snip ------------------------------------------
Task 2—Setting Up Asynchronous Shell Services
HW: 2, Firmware: 16, PLD Rev: 0
HW: 2, Firmware: 16, PLD Rev: 0
Cisco IOS Dial Services Quick Configuration Guide
2-13