Cisco C880 M4 Manuale operativo - Pagina 21
Sfoglia online o scarica il pdf Manuale operativo per Server Cisco C880 M4. Cisco C880 M4 48. System event log collection
Anche per Cisco C880 M4: Manuale di servizio supplementare (27 pagine), Manuale di installazione dell'hardware (23 pagine), Manuale di avvio rapido (2 pagine), Manuale di aggiornamento del firmware (5 pagine)
5.Hard Disk Drives
5.2. Removing/Installing Hard Disk Drive/Blank Insert
CAUTION!
Do not remove a hard disk drive from an operating array if you are not sure that it belongs to a
faultless and fault tolerance RAID configuration (RAID level 1, 5, 6, 10, 50 or 60), otherwise data will
be lost.
The hard disk drives must all be marked clearly so that they can be put back into the original bays
after an upgrade. If this is not taken into account, existing data can be destroyed.
To avoid temperature rise, replacing a hard disk should be finished within 5 minutes if the storage
subsystem is operating.
The hard disk drives which can be ordered for the storage subsystem are delivered pre-installed in frames.
Removing a hard disk drive from the frame may only be done in authorized repair centers.
Figure 12: Hard disk drive in frame
21