Cisco UCS B250 M1 Nota di installazione e manutenzione - Pagina 13
Sfoglia online o scarica il pdf Nota di installazione e manutenzione per Server Cisco UCS B250 M1. Cisco UCS B250 M1 34. Extended memory blade server
S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
•
Step 3
If you are shutting down all blade servers in a chassis, you should now disconnect the power cords from
the chassis to completely power off the servers. If you are only shutting down one server, you can skip
unplugging the chassis and move to removing the server.
Removing a Cisco UCS B250 Extended Memory Blade Server
Using UCS Manager, decommission the server using UCS Manager before physically removing the
server. To remove a Extended Memory blade server from the chassis, follow these steps:
Completely loosen the captive screws on the front of the blade.
Step 1
Remove the blade from the chassis by pulling the ejector levers on the blade until it unseats the extended
Step 2
memory blade server.
Step 3
Slide the blade part of the way out of the chassis, and place your other hand under the blade to support
its weight.
Step 4
Once removed, place the blade on an antistatic mat or antistatic foam if you are not immediately
reinstalling it into another slot.
If the slot is to remain empty, reinstall the slot divider (N20-CDIVV) and install two blank faceplates
Step 5
(N20-CBLKB1) to assure proper ventilation and cooling.
Installing a Cisco UCS B250 Extended Memory Blade Server
Extended memory blade servers reside within the upper slots of the chassis. To install an Extended
memory blade server, follow these steps:
If necessary, remove the slot divider (N20-CDIVV) from the chassis. To do this, follow these steps:
Step 1
a.
b.
OL-22474-03
Emergency shutdown—Press and hold the Power button for 4 seconds to force the main power off
and immediately enter standby mode.
Simultaneously pull up on the left side catch and push down on the right side catch as shown in
callout 1 of
Figure
4.
Pull the slot divider out of the chassis as shown in callout 2 of
it is needed at another time.
To reinstall the slot divider, align it with the dimples in the slot top and bottom and slide it back in
until it clicks into place.
Cisco UCS B250 Extended Memory Blade Server Installation and Service Note
Removing and Installing a UCS B250 Extended Memory Blade Server
Figure
4. Keep the slot divider in case
13