Cisco UCS B260 M4 Nota di installazione e manutenzione - Pagina 39

Sfoglia online o scarica il pdf Nota di installazione e manutenzione per Server Cisco UCS B260 M4. Cisco UCS B260 M4 46. Blade server
Anche per Cisco UCS B260 M4: Nota di installazione e manutenzione (50 pagine)

Cisco UCS B260 M4 Nota di installazione e manutenzione
Servicing the Blade Server
Table 5: TPM Support by Intel CPU Version
Intel CPU
Intel Xeon E7 v4
Procedure
Step 1
Install the TPM hardware.
a) Power off, decommission, and remove the blade server from the chassis.
b) Remove the blade server cover.
c) Install the TPM to the TPM socket on the server motherboard and secure it using the one-way screw that
is provided. See the figure below for the location of the TPM socket.
d) Return the blade server to the chassis, power it on, and allow it to be automatically reacknowledged,
reassociated, and recommissioned.
e) Continue with enabling TPM support in the server BIOS in the next step.
Figure 24: TPM Socket Location
1
TPM Version Supported
TPM 1.2
TPM 2.0
Front of server
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v4 CPUs
Enabling the Trusted Platform Module
Minimum UCS Manager (UCSM) Version
Release 2.2(8) or Release 3.1(2)
Release 2.2(8) or Release 3.1(2)
TPM socket on motherboard
2
31