Cisco UCS B440 Nota di installazione e manutenzione - Pagina 23
Sfoglia online o scarica il pdf Nota di installazione e manutenzione per Server Cisco UCS B440. Cisco UCS B440 33. High performance blade server
S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
Installing Memory
Check the server's service profile setting in UCS Manager before adding memory to make sure that the
new memory will be recognized. To install a DIMM into the blade server, follow these steps:
Open both DIMM connector latches, refer to callout 1 in
Step 1
Figure 12
1
3
Press the DIMM into its slot evenly on both ends until it clicks into place, refer to callout 2 in
Step 2
The DIMM connector latches will snap into place.
DIMMs are keyed and will only insert into their slot if the notch at the bottom of the DIMM is oriented
Note
correctly. Attempting to force an incorrectly oriented DIMM will damage the slot.
Press the DIMM connector latches inward slightly to seat them fully. Refer to callout 3 in
Step 3
Memory and Performance
This section describes the type of memory that the blade server requires, and its effect on performance.
The following topics are covered:
•
•
•
•
OL-22475-01
Installing DIMMs in the Blade Server
2
Supported DIMMs
Memory Arrangement
Memory Performance
Related Documentation
Cisco UCS B440 High Performance Blade Server Installation and Service Note
Figure
12.
1
3
2
Memory and Performance
Figure
12.
Figure
12.
23