Cisco UCS B460 M4 Nota di installazione e manutenzione - Pagina 30

Sfoglia online o scarica il pdf Nota di installazione e manutenzione per Server Cisco UCS B460 M4. Cisco UCS B460 M4 50. Blade server
Anche per Cisco UCS B460 M4: Scheda tecnica (7 pagine), Nota di installazione e manutenzione (46 pagine), Manuale di avvio rapido (2 pagine), Manuale di avvio rapido (5 pagine)

Cisco UCS B460 M4 Nota di installazione e manutenzione

Installing a New CPU and Heat Sink

Installing a New CPU and Heat Sink

Before installing a new CPU in a server, verify the following:
• The CPU is supported for that given server model. Refer to the Specification Sheet for this server to see
• A BIOS update is available and installed that supports the CPU and the given server configuration.
• If the server will be managed by Cisco UCS Manager, the service profile for this server in Cisco UCS
Caution
The Pick-and-Place tools used in this procedure are required to prevent damage to the contact pins between
the motherboard and the CPU. Do not attempt this procedure without the required tools, which are included
with each CPU option kit. If you do not have the tool, you can order a spare.
Procedure
Step 1
Required: To install a CPU in an empty socket, remove the protective cap that is intended to prevent bent or
touched contact pins. The pick and pull cap tool provided can be used in a manner similar to a pair of tweezers.
Grasp the protective cap and pivot as shown.
Step 2
Release the catch on the pick and pull tool by pressing the handle/button.
Step 3
Remove the new CPU from the packaging, and load it into the pick and place tool as follows:
a) Confirm that the pedestal is set up correctly for your processor. The pedestal ships configured with the
markings "LGA2011-R1" facing upward, and this is the correct orientation.
b) Place the CPU on the pedestal. The CPU corners should fit snugly at the pedestal corners and the notches
should meet the pegs perfectly.
c) Place the CPU pick and place tool on the CPU pedestal aligned with the A1 arrow pointing to the A1
registration mark on the pedestal.
d) Press the button/handle on the tool to grasp the CPU.
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v3 and E7 v2 CPUs
22
the list of supported CPUs. The Specification Sheets are available at this URL:
http://www.cisco.com/c/en/us/products/servers-unified-computing/ucs-b-series-blade-servers/datasheet-listing.html
Manager will recognize and allow the new CPU.
Servicing the Blade Server