Cisco UCS C240 M3 Manuale di configurazione - Pagina 22

Sfoglia online o scarica il pdf Manuale di configurazione per Server Cisco UCS C240 M3. Cisco UCS C240 M3 33. Nebs server
Anche per Cisco UCS C240 M3: Manuale di aggiornamento (10 pagine), Nota di servizio (11 pagine)

Cisco UCS C240 M3 Manuale di configurazione
After you have met at least the minimum requirements, click the Create Virtual Drive button to create a
RAID 10 volume. Navigate to the Virtual Drive Info tab to see the RAID 10 volume that has been created.
RAID 50 and 60 require a minimum of two drive groups with a minimum of three physical drives in each
drive group.
In the example here, RAID 60 is created with the minimum number of physical drives and drive groups.
Click the Create Virtual Drive button and navigate to the Virtual Drive Info tab to see the RAID 60 volume
that has been created.
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public.
Page 22 of 33