notified by events.
This operation is the UPOS Release 1.7 and subsequent releases
applied operation.
•
"Issue an Error Event for specified error occurrence during Check
insertion." radio button
Under the setting that this button is marked, EndInsertion method is
considered to be succeeded upon normal completion of analysis of the
data that is read from a check inserted by the method.
When the read data of MICR is normal or the data contains not
analyzable characters, these conditions are notified by events.
Whether the read data and reading operation of MICR are illegal are
indicated by the set value of ResultCode and ResultCodeExtended
properties.
This operation is the same as the default operation of UPOS Release
1.6 (previous versions of Ver. 2.30) applied operation.
Default setting of above radio buttons is "Issue an Error Event for every error
occurrence during Check insertion.".
Regarding the variety of events and values of ResultCode and
ResultCodeExtended are described, please refer to the Section 8 of this
manual.
"Automatic check remove on read error" check box:
This check box setting can be done only when "Issue an Error Event for
specified error occurrence during Check insertion." radio button under "Error
handling options during Check insertion" is selected.
This check box is inapplicable when "Issue an Error Event for every error
occurrence during Check insertion." is selected.
When a read data is in those conditions as below, the check is removed:
1. The entire data is incorrect. (Neither an incorrect insertion, nor an
incorrect sheet, etc.)
2. Longer than the prescribed length
3. Blank check sheet
If one of the data is read as "?", the check will not be removed.
For the EPSON TM-U950, this setting is the default and cannot be changed.
The TM-U950 cannot translate error data as "?".
APPLICATION DEVELOPMENT GUIDE
MICR (EPSON TM Series)
5
Version 3.00 Feb. 2019