DigiWeigh A12 Manuale - Pagina 5

Sfoglia online o scarica il pdf Manuale per Bilance DigiWeigh A12. DigiWeigh A12 7.

Beep 2: Beep when the weight falls into the weight range.
Beep 3: Beep when the weight falls out of the weight range.
Press [TARE] key to select desired mode then press [FUN] key to set High-limit:
Now there are 6 zeros on the screen. Press [ZERO] key to move the editable digit
(blinking) and press [TARE] to change the value. When you are done, press [FUN] to
set Low-limit. When you are done, press [FUN] to confirm. The screen will go back to
"F4
CHK"
To disable the check-weighing function, press [UNIT] key to set both high-limit and low-
limit to zero.
2.10 PRINTING (WHEN F3 KEY=2)
Set P 10 as "RS" (We will show to how to set P value later on.)
In the weighing mode, press [MOD] to print.
Chapter 3 Setting Parameters
To enter parameter setting: Turn on the indicator and press [ZERO] key when the
indicator is still warming up.
3.1 "F1 CLK" DATE AND TIME SETTING
Press [FUN] key to show the current time. If it is not correct, adjust it as following:
Press [ZERO] key to change hour (the hour is blinking). Press [TARE] to add up until it
shows the correct hour. Press [ZERO] to move to the minutes (the minutes are blinking).
Press [TARE] to add up until it shows the correct minute. Press [ZERO] to move to the
seconds (the seconds are blinking). Press [TARE] to add up until it shows the correct
second.
Press [FUN] to confirm and move to date mode setting. There are 3 date showing
modes:
"YY-MM-DD", "MM-DD-YY" and "DD-MM-YY". Press [TARE] key to switch between and
press [FUN] to confirm then move to date setting. Use the same way as timing setting
to set the date. Press [FUN] to confirm and exit. During the time or date setting, you
may press [MOD] anytime to cancel and exit. System will not save the changes. Press
[TARE] to move to the next parameter.
3.2 FAST CALIBRATION FOR ZERO POINT AND FULL RANGE POINT
Press [#] while it is initialization, it enters into the calibration mode.
3.2.1 Fast calibration for zero point:
At any time before it shows [nOLOAD], press [FUNC], it keeps the original division,
decimal point, full range and enter into the zero point calibration mode. Press [ZERO]
Floor / Pallet Scale
4