Acuity Brands Lighting AARP Manuale - Pagina 15

Sfoglia online o scarica il pdf Manuale per Luce per esterni Acuity Brands Lighting AARP. Acuity Brands Lighting AARP 18.

Installation Instructions
RSX LED
AAWB/AAWSC INSTALLATION INSTRUCTIONS
NOTE: Luminaire can be tilted up to 90 degrees above horizontal
Tools Required:
• 9/64" Allen Wrench
• 5/32" Allen Wrench
• 3/16" Allen Wrench
• Flathead Screwdriver (AAWSC only)
Minimum Square Pole: 3.5" Face
Minimum Round Pole: 3.2" Diameter
CAUTION: APPLY A CONTINUOUS BEAD OF WEATHER – PROOF CAULKING BETWEEN MOUNTING BASE PLATE AND WALL TO
ENSURE WEATHER–TIGHT INTEGRITY OF ELECTRICAL COMPONENTS (See Fig 15a & 15b)
1. Install the wall-mount base plate, refer to steps 1-3 outlined in the WBA/WBASC installation instructions on sheet 9. Note
that the image above shows the AAWSC option.
2. Before mounting the luminaire, remove the arm cover (See figure 20 on the previous page) and unpack the luminaire input
wires, if necessary, to make routing supply wires into the arm cavity easier.