DESCRIPTION OF CONTROL
1. Icons weather forecast
15. Display low battery indicator
2. Historical barometric pressure
16. Indoor temperature/humidity
3. Trend of barometer display
MAX/MIN records
4. Outdoor temperature / humidity
17. Tendency indoor humidity
external sensor
18. Comfortable level
5. Tendency outdoor temperature
19. Sunrise time display
6. Outdoor sensor signal strength
20. Select city
7. Channel external sensor
21. Sunset time display
8. Sensor low battery indicator
22. Tide level
9. Outdoor temperature/humidity
23. Moon phase
MAX/MIN records
24. Alarm Clock icons
10. Tendency outdoor humidity
25. Time display
11. Temperature alert
26. Weekday
12. Freezing alert
27. Calendar
13. Indoor temperature / humidity
28. MODE button
14. Tendency indoor temperature
29. UP/MAN/MIN button
30. SNOOZE button
31. CITY button
32. DOWN/ALERT button
33. LIGHT button
34. CHANNEL button
35. HISTORY button
36. Battery Compartment 3xAAA (batteries not included)
37. External power supply socket
38. Wireless signal indicator
(Flashes when data is being sent to the display unit)
39. Integrated hang hole
40. TX button
35
41. TX channel selector, select external sensor channel
42 . Compartment 2xAA batteries (batteries not included)
MAIN FUNCTION
a. The week display in English
b. Calendar (Month/date, 2000-2099 Default Year 2012)
c. Time (Hour / Minute)
d. Indoor temperature / Humidity
e. Wireless outdoor temperature / humidity
f. C/F degrees select-able
g. Alarm and snooze function
h. Weather forecast: Sunny, Slightly Cloudy, Cloudy, Rainy, Sleety, Snowy
i. History chart for pressure (12Hr)
37
j. Low battery indicator: main unit & transmitter
k. Trends
l. High / Low daily records
m. Comfort indicator
n. 150 Major european cities setting for Sunrise / Sunset / Moon Phase / Latitude
and Longitude
Batteries:
1. Receiver :3 x AAA / R03 / UM-4 Size Batteries(36)
2. Transmitter : 2 x AA / R03 / UM-4 Size Batteries(42)
Extended periods of cold temperature (below-20°F/-28.8°C) can cause alkaline
batteries to function improperly. This will cause the outdoor wireless sensor to stop
transmitting temperature readings. Use lithium batteries in these low temperature
41
conditions to ensure continued operation for wireless sensors placed outdoors.
NOTE: Rechargeable batteries are not recommended due to higher operating
voltages.
Alkaline Batteries: -20°F to 140°F (-28.8°C to 60°C)
Lithium Batteries: -40°F to 140°F (-40°C to 60°C)
Temperatures below - 20°F (-28.8°C)
Require lithium batteries in the outdoor sensor.
42
3. When the Main Weather Station batteries are low, a battery sign will appear next
to INDOOR lettering on the LCD(15). The same sign will appear next to the
OUTDOOR lettering when the Outdoor Sensors` battery is low(8).
LCD Display:
Indoor temperature:
1. Operating temperature range = 0°C to 50°C ( 32°F to 122°F)
2. Accuracy ± 2 degrees celsius 0°C to 50°C( 32°F to 122°F)
3. Resolution = 0.1°C
4. When above 122°F (50°C) the temperature sensor should continue to read the
correct temperature as long as the LCD display continues to function in these
extreme conditions.
5. When below 32°F (0°C) the temperature sensor should continue to read
correctly as long as the LCD display continues to function in these extreme
conditions.
Indoor Humidity:
1. Operating humidity range = 20% RH to 95%
2. Accuracy +/- 5% RH (@25oC , 30%RH to 80%RH)
3. Accuracy +/- 8% RH (@25oC , 20%RH to29%RH;80%RH to 95%RH)
4. Resolution = 1 % RH
Outdoor temperature:
1. Operating temperature range = -29°C to 60°C ( -20°F to 140°F)
2. Accuracy ± 1 degrees celsius from 0°C to 50°C ( 32°F to 122°F)
3. Accuracy ±2 degrees celsius from -29°C to 0°C
60°C(from 122°F to 140°F)
4. Resolution = 0.1°C
5. When above 140°F (60°C) the temperature sensor should continue to read the
correct temperature as long as the LCD display continues to function in these
extreme conditions.
6. When below -20°F (-29°C) the temperature sensor should display continue to
read correctly as long as the LCD display continues to function in these extreme
conditions.
Outdoor Humidity:
1. Operating humidity range = 20% RH to 95%
2. Accuracy +/- 5% RH (@25oC , 20%RH to 90%RH)
3. Accuracy +/- 8% RH (@25oC , 20%RH to 30%RH;80%RH to 95%RH)
4. Resolution = 1 % RH
Barometric pressure:
1. Measure range=800mb to 1100mb
2. Resolution=1mb
3. Measuring time interval: every 12 minute
Default SETTING:
1. Time: 00:00am
2. Date/Day: Jan 1st, 2012, Sunday
3. Temperature: ºC
4. Weather Forecast Icons: PARTLY SUNNY
Operations:
Power On:
The LCD will display all segments for a few second when batteries are inserted.
Position the station and the sensor directly next to one another. Insert the batteries
into the outdoor sensor within the next 2 minutes.
Display / Keys Details:
There are in total 8 keys (6 Front & 2 Back) for the Weather Station. They are:
(Front(28-33)) MODE, CITY, UP/MAX/MIN, DOWN/ALERT, SNOOZE, LIGHT.
(Back) CHANNEL(34) & HISTORY(35)
MAX/MIN operation:
1. The maximum and minimum values of temperature and humidity are stored
automatically.
2. In Normal mode press "UP/MAX/MIN" once to view the maximum readings and
press again to view the minimum readings.
3. After 5 seconds without use the display will return to normal mode displaying the
live readings.
4. Press and hold "UP/MAX/MIN" button to delete these readings which will also
automatically delete at midnight (12:00AM) daily.
To set Clock / Date Manually :
Press and hold the MODE key to enter setting mode. Use UP/MAX/MIN and
DOWN/ALERT to select desired value. The sequence of selection is:
1. 12/24-HOUR: 12Hr or 24Hr will flash. Press and release the UP or DOWN button
to select the 12-hour or 24-hour time. Press and release the MODE button to
continue.
2. C/F: The °C or °F indicator will now blink on the display. Press "UP" or "DOWN"
to select the temperature unit and confirm your setting by pressing MODE.
3. Set the hours, minutes, year, month and date in the same way.
Note:
I. If no buttons are pressed in a 20 second period the set mode will time out and
return to live display mode, reflecting whatever adjustments were made by the
user before timing out.