Installation Instructions
RSX LED
Figure 1
3.
If the bar with the #8 drilling pattern
(Fig 2a) does not line up with existing holes,
use the universal mounting bar (Fig 2b) with
the sliding thread.
Insert one of the included 3/8 mounting
bolts through the top hole of the pole and
thread into the mounting bar. For a round
pole, the round pole adapter (RPA) is re-
quired and must be placed between the pole
and the fixture as shown with the curved
side contacting pole and flat side facing away
from pole (Fig 2c).
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
RSX SPA/RPA & ESPA/ERPA INSTALLATION INSTRUCTION
Tools Required:
•
3/8" Socket Wrench
•
9/64" Allen Wrench
Minimum Square Pole: 3.5" Face
Minimum Round Pole: 3.2" Diameter
1.
Loosen the captive screws of the arm cover (Fig 1) to
access the pole mounting area
2.
Two mounting bars are included in the installation kit:
a.
The shorter bar is used for #8 Lithonia drilling pattern
and has 3 holes. The top and bottom hole are threaded.
b.
The longer bar has one top hole and a slot with a slid-
ing threaded hole to be used on poles with existing drill pat-
terns.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
Page #2