Installation Instructions
HLA LED
3)
Insert one 3/8 mounting bolt through the top hole of
the pole.
Thread this bolt into the flat bar stock top hole.
The top hole of the luminaire is a keyhole slot.
Take the luminaire and hang the fixture from this top bolt
(See Figure 3).
Do not tighten yet.
Figure 4
5)
Insert the wires through the keyhole slot and pull
them into the pole (See Figure 5).
Make sure that wires are not pinched and tuck excess wire up
into the luminaire mounting area.
Reinstall the access door that was removed.
Make wire connections in the pole, observing proper voltage
and polarity.
Connect green ground wire from the fixture to the field
ground wire.
Secure wires; push back into pole and replace pole cap.
Troubleshooting: If this fixture fails to operate properly, check to make sure: • The fixture is wired correctly.
grounded correctly.
• The line voltage at the fixture is correct. If all these variables have been checked and the fixture still
does not operate as specified, contact your local Lithonia Lighting distributor.
4)
hole of the bar stock plate.
Tighten the two bolts with a 9/16 socket with to 20-30 ft-lbs
(overtightening can damage components and void warran-
ties) (See Figure 4).
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 800-279-8041 • Fax: 770.918.1209 •
© 2015 Acuity Brands Lighting, Inc. All rights reserved.
Thread the second bolt into the bottom threaded
www.lithonia.com
Figure 3
Figure 5
• The fixture is
Part Number: RJ521392 Rev A
Revision Date: 4/4/16