AEMC instruments CA7027 Manuale d'uso - Pagina 17

Sfoglia online o scarica il pdf Manuale d'uso per Strumenti di misura AEMC instruments CA7027. AEMC instruments CA7027 20. Fault mapper pro graphical tdr
Anche per AEMC instruments CA7027: Manuale d'uso (20 pagine)

AEMC instruments CA7027 Manuale d'uso

4.13 Typical Fault Displays

The following table shows typical fault traces to assist you in the
identification of faults using the CA7027:
Type
Cat5 STP
Cat5 UTP
Coax Air
Coax Air Space
Coax Foam PE
Coax Solid PE
Fault Mapper Pro
Find Quality Products Online at:
Continuous Scanning Mode: Fires pulses into the cable
under test at the rate of 6.7 pulses per second. In this
mode the Fault Mapper Pro
intermittent cable faults.
Vp
Z
72
100
70
100
98
50/75
94
50/75
82
50/75
67
50/75
®
Model CA7027
GlobalTestSupply
www.
®
is able to more easily identify
Type
T/Pair Jelly PE
T/Pair PE
T/Pair PTFE
T/Pair PVC
T/Pair Paper 72nF
T/Pair Paper 83nF
.com
Vp
Z
64
100
67
100
71
100
58
100
88
100
72
100