Dimac J06 Manuale di installazione - Pagina 2
Sfoglia online o scarica il pdf Manuale di installazione per Apparecchiature industriali Dimac J06. Dimac J06 6.
❖J06 Pass line
The pass line height is decided by combination a plate and a holder.
CAUTION
The plate-center equals the feeding rolls -center.
It is necessary to tighten 4 points with a bolt to fix the holder on the plate.
Plate
180
100
From top
A,B,C,D
Plate
Hole
height
position
A
B
h=0
C
D
A
B
h=25
C
D
A
B
h=50
C
D
❖Mounting position
Top view
Mounting position
h g f e
9 8 7 6 5 4 3 2 1
❖Balance of confirmation
210
Plate
Pass line (mm)
height
78~128
63~113
h=75
48~98
33~83
103~153
88~138
h=100
73~123
58~108
128~178
113~163
h=125
98~148
83~133
2&6, 3&7, 4&8, 5&9
d c b a
70
Bolster
2
Holder
70
Hole
Pass line (mm)
position
A
153~203
B
138~188
C
123~173
D
108~158
A
178~228
B
163~213
C
148~198
D
133~183
A
203~253
B
188~238
C
173~223
D
158~208
1: not use (a~h:for J15)
J06
❖Assembly drawing of the bracket
h
Bolster