Dimplex BOF4056 Manuale di servizio - Pagina 12
Sfoglia online o scarica il pdf Manuale di servizio per Camino da interno Dimplex BOF4056. Dimplex BOF4056 12.
Anche per Dimplex BOF4056: Manuale d'uso (19 pagine)
PROBLEM
Heater
Heater is not turning off
Heater is not turning on
Heater is turning off after a
couple of minutes of operation
Heater emits an odor
Heater fan turns on but heater
lacks heat
Heating element is glowing red
Heater fan runs continuously
Noise
Excessive noise with the heater
on
12
CAUSE
Improper operation
Defective 3 position switch
Defective thermostat
Improper operation
Loose wiring
Defective heater assembly
Defective 3 position switch
Build up of dirt/dust in heater assembly
Defective Heater Assembly
Normal Operation
Defective heater assembly
Improper operation
Loose wiring
Defective heater assembly
Normal Operation
Defective heater assembly
Loose wiring
Defective momentary switch
Defective heater assembly
Dirty heater assembly
Defective heater assembly
SOLUTION
Refer to Operation Section
Replace 3 position switch
Replace thermostat
Refer to Operation Section
Trace Wiring
Replace heater assembly
Replace 3 position switch
Ensure that exterior intake louvers and firebox cavity
are free of dirt/dust.
Replace Heater Assembly
Normal operation is when the heater emits an odor
for a brief period after the heater is initially turned on.
The heater is burning off any dust accumulated during
manufacturing or operation.
Replace heater assembly
Refer to Operation Section
Trace wiring in unit
Replace heater assembly
Small glowing sections of the element are considered
normal.
If larger glowing sections are causing the heater to trip
the thermal cutout, unplug unit, discontinue use and
replace heater assembly.
Trace wiring in unit
Replace momentary switch
Replace heater assembly
Ensure that exterior intake louvers and firebox cavity
are free of dirt/dust.
Replace heater assembly
www.dimplex.com