Philips AZ127/73/93 Manuale di servizio - Pagina 11

Sfoglia online o scarica il pdf Manuale di servizio per Impianto stereo Philips AZ127/73/93. Philips AZ127/73/93 33.

Philips AZ127/73/93 Manuale di servizio
Philips Consumer Lifestyle
BU AVM

3. Technical Specifications

Power Supply

3.1
3.1.1
Type and versions
Built in transformer will be used for all models and stroke versions.
Versions
Region/Country
12/05
EUROPE / UK
37
NAFTA
55
LATAM
98
APAC
94
India
All requirements per defined for each country should be met with sufficient testing.
3.1.2
Surge Immunity (Lightning Test)
The product shall withstand mains interference's of:
Differential mode:
2kV/2 ohm criteria C for Europe.
6kV/12 ohm criteria C for NAFTA.
Parameters:
Bi-wave
Open circuit voltage: 2/50us
Short circuit current: 8/20us
From +/1kV to +/-2kV (for Europe) or +/-6kV (for Nafta) in steps of 1kV.
10 shots per combination.
One shot per minute.
Serial impedance: 2 Ohm for Europe, 12Ohm for Nafta.
Polarity and phase: Positive (phase 90º) & Negative (phase 270º)
Common mode:
6kV/2 ohm criteria C for Europe.
6kV/12 ohm criteria C for Nafta.
Parameters:
Ring-wave (100kHz)
From +/3kV to +/-6kV in steps of 1 kV.
10 shots per combination.
One shot per minute.
Serial impedance: 2 Ohm for Europe, 12Ohm for Nafta
Polarity and phase: Positive (phase 90º) & Negative (phase 270º)
Reference: IEC61000-4-5 and for USA: 3135 019 8029 Reliability evaluation.
Requirements:
Apparatus should fulfil the leakage current requirements of IEC60065 point 9.1.1 (UAN-D1631)
Defects or permanent deviations are not allowed.
-
2
3
Tang Bing
NAME
CHECK
Philips Electronics (China) Ltd.
No.12 ShiHua Road, FuTian Free Trade Zone,
ShenZhen, China
Power supply
AC 207~253V
AC 99~132V
AC 93.5~146V; 198~264V
AC 207~253V
AC 170~280V
AZ127/320/328/329
18
2012-11-16
DATE
.
10
190
-
11
BU HAV Consumer Lifestyle, Philips
©
PHILIPS
-
2012-07-18
-
2012-10-24
-
2012-11-11
A4