Sfoglia online o scarica il pdf Manuale dell'operatore per Monitor MSI MSI-8000HD. MSI MSI-8000HD 48. Rf remote display
3.10 Total Remote Devices
Pressing the
Fx-ttL.rd
Sensor summing must be enabled in the COMM Setup Menu. If the "Pairs" or "Both"
modes are enabled in the COMM setup menu, then pressing the
scroll through the available combinations.
It is a common setup to program
Note
Remote Devices) to allow quick switching between individual channel
displays (with
3.11 Tare
The
key is redundant in the MSI-8000HD since it has a permanent
Fx-Tare
This was done for consistency across the ScaleCore based product line. There is no
need to program a function key to "TARE."
key displays the summed weight of RF connected sensors.
) or the summed weight (with "ttL.rd").
F1
for SCAN and
User Defined Function Keys
Fx-ttL.rd
F2
for "ttl.rd" (Total
TARE
key will
key.