Lamp replacement (Continued)
3
Remove the lamp cover.
Loosen the 2 screws, then pull up to the
direction of the arrow with your fingers on the
area shown in the figure to remove the lamp
cover.
4
Pull out the lamp.
Loosen the 2 screws holding the lamp in place,
and pull up the handle to remove the lamp.
5
Mount the new lamp.
Align the orientation, press down until the bottom is
reached, and lock in place using the two lamp
locking screws.
6
Replace the lamp cover.
Align the cover, and press it in, then tighten the
screws loosened in step
3
until the lamp cover is
no longer loose.
7
Reset the lamp timer.
See the lamp's manual for instructions on resetting
the lamp timer.
Notes and Precautions
• Press the
button twice to display (a rough guide) the time of lamp use, the Lamp time
item, in the Status display menu.
p.28
• It is recommended that the lamp should be replaced after 2,000 hours of use. When
Lamp time reaches 2,000 hours, the
disappears when you press
button.
• Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the
lamp may fail to come on
p.35
, and the lamp's lifetime may be shortened.
• Always replace the lamp with a new one.
• The lamp is made out of glass. Do not touch the glass surface with your bare hands,
bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.)
Used Lamps
This projector's lamps contain trace amounts of environmentally harmful inorganic
mercury. Be careful not to break used lamps, and dispose it in accordance with local
regulations.
1
3
2
1
4
2
2
5
1
icon and a message will appear. This display
34

Others

Trouble indications

The indicator lights inform you of internal abnormalities.
FAN
TEMP
LAMP
ON
No power
⇒ Problem with projector
(Off)
• Unplug the power cord, and contact your dealer.
Lamp went out during use, or won't come on
FAN
TEMP
LAMP
ON
⇒ Lamp temperature is high so that it is difficult to turn on, the lifetime of
(Red lit) (Red lit)
the lamp has ended or the projector is malfunctioning.
• Unplug the power cord and wait for a short while, then turn the power
back on.
• If a lamp burns out, replace it with a new one.
❈ After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
Power went out during use
FAN
TEMP
LAMP
ON
⇒ Internal overheating, or the outside temperature is too high.
(Green lit) (Red lit)
(Red lit)
• Place the projector so that the air intake and exhaust are not blocked.
• Unplug the power cord and wait for a short while, then turn the power
Or
Or
(Orange lit)
(Off)
back on.
• Clean the air filter.
Or
❈ The
icon will appear before the power goes out.
(Green lit)
❈ After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
Power went out during use
FAN
TEMP
LAMP
ON
⇒ Problem with internal cooling fan.
(Red lit or flashing)
(Red lit)
• Unplug the power cord, and contact your dealer.
❈ The
icon will appear before the power goes out.
Or
❈ After approx. one minute of abnormal display, the projector returns to
(Orange lit or flashing)
the standby state waiting for internal cool down.
Power went out during use, or power won't come on
FAN
TEMP
LAMP
ON
⇒ The lamp cover is not properly attached.
(Orange
(Red lit)
• Unplug the power cord, and reattach the lamp cover.
flashing)
❈ After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
PRECAUTIONS
• Make sure to unplug the power cord if something goes wrong.
• If the power cord is unplugged before cooling is complete, give the lamp enough time to
cool before plugging it back in. If the lamp overheats, it may fail to light. Unplugging the
power cord repeatedly when the temperature is high will shorten the life of the lamp.
(Even if you are not concerned about lamp lifetime, the light may not come on if you do
not wait at least 3 minutes.)