Dimplex DAC 9000 Manuale d'uso - Pagina 3
Sfoglia online o scarica il pdf Manuale d'uso per Condizionatore d'aria Dimplex DAC 9000. Dimplex DAC 9000 11. Dimplex dac 9000 air conditioner user manual
The ventilation mode "moves" the air allowing for its recycling.
The cooling mode, a refrigerating circuit (compressor), cools the room by transferring
the heat from inside to outside though the air exhaust hose.While cooling, the air-
conditioning unit also dehumidifies the room air.
Humidity absorbed from the air condenses and turns into water that is collected in the
internal tank.The water level in the tank is automatically controlled by a float and micro
switch and when the preset level is exceeded the indicator above the 'Power' Switch will
light and the compressor will shut off automatically, the fan motor will stay on circulating
the air. At this time, you must empty the water tank as described in "Drainage" page 9.
Please Note!
During very humid conditions it will be necessary to empty the water tank more
frequently.
An added feature of this model, when enough water is collected in the tank, water is
automatically pumped up and through the condenser.The recycled water cools the
condenser which increases the cooling capacity output also evaporating some of the
water alleviating the frequency of having to empty the water tank.
Dehumidification, in the cooling mode your air-conditioner does remove moisture from
the air however another feature of this machine it, can be set up to operate as a
Dehumidifier with better moisture removal performance.
Specifications.
Cooling Capacity
Power consumption
Air Volume (max setting)
Humidity removal capacity
Net weight
Power supply
Compressor
Refrigerant
Fan Speed
Timer
Thermostat
Dimension(WxDxH)
Test Conditions
9000BTU/hr
2270cal/hr
2638 watts
830 Watts
3
400m
/h
18L/day
31kg
230-240V/50Hz
Rotary
R22
2
1-8 hours
18-32°C
377x400x750 mm
Temperature 27°C
Humidity 60%
3