Intended Use

1
Intended Use
Safety switchgear to monitor the speed of three-phase and single-phase motors without sensor.
Two speed thresholds are possible: minimum speed and maximum speed.
The unit meets Cat. 4/ PL e acc. to ISO 13849-1, SIL (CL) 3 acc. to IEC 62061 and IEC 61508.
Usage in safety current circuit according to VDE 0113 T.1

Approvals

Safety parameters

The unit meets Cat. 4/ PL e and SIL (CL) 3.
Parameter
PFH
MTTF
d
DC
avg
table 1-1: Safety parameters

Ordering data

Speed monitoring, sensorless
6
Value
1,56 E-09 1/h
553 a
95%
Description
0-600Hz, 2 contact outputs,
start-up monitoring
Note
1,6 % von SIL 3
HIGH
(HIGH)
Type
ID-No.:
DN3PD1
33PD02
18-09-27 / 33pd02-V0743