DINA DNSR-2R Manuale di istruzioni originale - Pagina 7
Sfoglia online o scarica il pdf Manuale di istruzioni originale per Apparecchiature industriali DINA DNSR-2R. DINA DNSR-2R 8.
DNSR-2R Original Betriebsanleitung Original Instruction Manual
Technical data
Power supply
Current drain
Fuse
Operating temperature
Storage temperature
Vibration resistance
Maximal cable cross section
Tightening torque with screw terminal
Connection wire
Housing material
Protection class
Rated Isolation voltage
Impulse withstand voltage
pollution degree 2 environment
Technical data of inputs
S12, S34
S22, S44
Technical data of the contact outputs
Contacts closed to power supply, 14, 24 and 34
(NO)
Potential free contacts
Switch current according to IEC/EN 60947-4-1
According to IEC/EN 60947-5-1
Mechanical life
Contact material
Maximal cycles
Reaction time / Drop out time
Kontaktlebensdauer
10.000
5000
AC1.
230V
AC15:
230V
1000
500
DC13:
24V
100
50
10
Schaltstrom (A) / Switching current (A)
DNSR-2R
Contact life
DC1:
24V
Stand 15.08.2016
Seite 7 von 8
General technical data
24VDC +/- 10%
ca. 40mA relay off, ca. 70mA relay on
Internal PTC fuse 200mA
-10°C to +60°C /
40°C to +80°C
Sin 10 – 50 Hz, 0,35mm, 10 cycles, 1 Octave /min
1,5 mm² with wire end sleeve
0,5-06 Nm
60/75°C copper
Polyamide PA non-reinforced
Installation in a closed cabinet with ≥ IP54, terminals: IP20
250V AC not for the contacts 14, 24, 34
4KV, not for the contacts 14, 24, 34
15V ± 0.5V, internal at S11, S33 test against other voltage
12V ± 0.5V, internal at S21, S43 test against other voltage
Minimal: 3mA, maximal: 0,5A from the power supply of the unit
Minimal: 10mA, maximal: 6A, contact fuse 5A slow
AC1: 230V / 6A, DC1: 24V / 6A, 10
4
AC15: 230V/ 3A, 7x10
cycles, DC13: 24V/ 4A, 4x10
6
> 20 x 10
cycles
AgNi10
360 cycles/h with maximal switching current AC15+ DC13
Typical 10ms / Typical 6ms
Abmessungen
Date 2016-08-15
5
cycles
4
cycles
Dimension
99
Page 7 von 8
22,5