Pioneer Elite PRO-R06U Manuale di formazione - Pagina 31

Sfoglia online o scarica il pdf Manuale di formazione per Monitor Pioneer Elite PRO-R06U. Pioneer Elite PRO-R06U 47. Pioneer 6th generation plasma media receivers

Pioneer Elite PRO-R06U Manuale di formazione
2.2. FUNC.CHECK Function Check mode
Operation item
No.
1
FAN
2
AFT
1. FAN
Forces the setting of FAN speed (MAX: High speed/MIN: Low speed/STOP: Stops FAN).
NORMAL is for normal operation (i.e. the rotational speed changes according to temperature change).
During Sevice Factory mode, the temperature sensor will operate accordingly to the displayed data.
After exiting the Service Factory mode, the compulsive setting is cancelled, and the FAN wil return to
normal operation mode.
If rotational speed was compulsorily changed via 232c command, make sure to return the speed to
normal operation mode when finished.
2. AFT
Exclusively used for production line.
AFT action is stopped, and assign whether to track down or not during channel tuning.
Display
Forces the setting of FAN speed.
Controls AFT action by turning ON/OFF.
Figure. FAN
Command
FCN+S00
NORMAL
FCN+S01
MAX
FCN+S02
MIN
FCN+S03
STOP
31
Content
Detail
RS232C
FCN
AFT