RS-232C Adjustment
5) <QSS> Obtaining SETUP information
Sequence
Data Content
1
STX
2
Command echo-back
3
COLOR TEMP.
4
POWER MGT.
5
AUTO POWER OFF
6
DNR
7
MPEG NR
8
CTI
9
PURECINEMA
10
COLOR DECODING
11
COLOR SYSTEM
12
DVI SET UP (PLUG/PLAY)
13
DVI SET UP (BLACK LEVEL)
14
BRT.ENHANCE
15
SUB VOLUME
16
Main input function
17
Main screen size information
18
Check sum
19
ETX
Note 1) In the case of set data that cannot be output because of the type of input signal, dummy data is output.
6)
<QSO> Obtaining menu integrator/OPTION information
Sequence
Data Content
1
STX
2
Command echo-back
3
ENERGY SAVE
4
PROGRAM/REPEAT timer
5
SCREEN MANAGEMENT (ORBITER)
6
SCREEN MANAGEMENT (SOFT FOCUS)
7
AUTO SETUP MODE
8
AUTO FUNCTION
9
PIP DETECT
10
SPLIT FREEZE
11
SCREEN MASK
12
SIDE MASK R-LEVEL
13
SIDE MASK G-LEVEL
14
SIDE MASK B-LEVEL
15
VIDEO WALL (MODE)
16
VIDEO WALL (POSITION)
17
VIDEO WALL (TYPE)
18
VIDEO WALL (POWER ON DELAY)
19
VIDEO WALL (ABL LINK)
20
Spare (dummy)
21
FAN CONTROL
22
OSD DISPLAY
23
OSD SIZE
24
OSD ANGLE
25
FRONT INDICATOR
26
COLOR MODE
18
Size
1 Byte
02hex
3 Byte
QSS (fixed)
1 Byte
1: LOW 2: MID LOW 3: MIDDLE 4: MID HIGH
5: HIGH Note 1)
1 Byte
0: OFF
1: ON
1 Byte
0: DISABLE
1: ENABLE
1 Byte
0: OFF
1: LOW
2: MIDDLE
1 Byte
0: OFF
1: LOW
2: MIDDLE
1 Byte
0: OFF
1: ON Note 1)
1 Byte
0: OFF
1: ON Note 1)
1 Byte
1: RGB 2: COMP1 3: COMP2 Note 1)
1 Byte
1: AUTO
2: NTSC
3: PAL
6: PAL M 7: PAL N Note 1)
1 Byte
1: PC
2: VIDEO Note 1)
1 Byte
1: LOW 2: HIGH Note 1)
1 Byte
0: OFF
1: ON Note 1)
2 Byte
00 to 20
3 Byte
Same as item 9 of QST commands
1 Byte
Same as item 11 of QST commands
2 Byte
1 Byte
03hex
Size
1 Byte
02hex
3 Byte
QSO (fixed)
1 Byte
0: STANDARD1
1: MODE1
4: AUTO
5: MUTE
1 Byte
0: OFF
1: PROGRAM
1 Byte
0: OFF
1: MODE1
2: MODE2
1 Byte
0: OFF
1: 1
2: 2
3: 3
1 Byte
0: INACTIVE 1: ACTIVE
1 Byte
0: OFF 1: INPUT1 2: INPUT4
1 Byte
0: INACTIVE 1: ACTIVE
1 Byte
0: OFF 1: SIDE BY SIDE 2: PIP
1 Byte
0: OFF 2: INVERSE 3: WHITE 4: RED 5: GREEN 6: BLUE
7: YELLOW
3 Byte
000 to 255
3 Byte
000 to 255
3 Byte
000 to 255
1 Byte
0: OFF 1: 1 screen 2: 4 screens (2 x 2) 3: 9 screens (3 x 3)
4: 16 screens (4 x 4) 5: 25 screens (5 x 5)
2 Byte
01 to 56
1 Byte
0: NORMAL 1: ADJUSTED
1 Byte
0: OFF
1: ON
2: MODE1
1 Byte
0: OFF
1: ON
1 Byte
* (FIX)
1 Byte
1: AUTO
2: MAX
1 Byte
0: OFF
1: ON
1 Byte
0: LARGE
1: SMALL
1 Byte
0: H
1: V
1 Byte
0: OFF
1: ON
1 Byte
1: NORMAL 2: STUDIO
Remarks
3: HIGH Note 1)
3: HIGH Note 1)
4: SECAM
5: 4.43NTSC
Remarks
2: MODE2
3: MODE3
6: STANDARD2
2: REPEAT
3: MODE3
4: 4
3: MODE2