AEONTEC ZW096 Manuale - Pagina 8
Sfoglia online o scarica il pdf Manuale per Unità di controllo AEONTEC ZW096. AEONTEC ZW096 9. Low-cost z-wave switch plugin module specifically used to enable z-wave command and control (on/off) of any plug-in too
Parameter Number Definitions (8 bit):
Parameter
Description
Number
Hex / Decimal
0x03 (3)
Current Overload Protection. Load will be closed when the
Current overrun (US: 16.5A, EU:14A, AU:10.5A) and the
time more than 2 minutes (0=disabled, 1=enabled).
0x1 (20)
Configure the output load status after re-power on
(0=last status, 1=always on, 2=always off)
0x21 (33)
Set the RGB LED color value for testing.
Value1: Reserved
Value2: Red value
Value3: Green value
Value : Blue value
0x50 (80)
Enable to send notifications to associated devices (Group 1)
when the state of Micro Switch's load changed (0=nothing,
1=hail CC, 2=basic CC report).
0x51 (81)
Configure the state of LED when it is in 3 modes below:
0= The LED will follow the status (on/off) of its load (Energy
mode).
1= When the state of Switch's load changed, The LED will
follow the status (on/off) of its load, but the red LED will
turn off after 5 seconds if there is no any switch action
(momentary indicate mode).
2= Night light mode.
0x53 (83)
Configure the RGB value when it is in Night light mode.
Value1: Red color value
Value2: Green color value
Value3: Blue color value
0x5 (8 )
Configure the brightness level of LED indication (0%-100%)
0x5A (90)
Enables/disables parameter 91 and 92 below (1=enabled,
0=disabled).
0x5B (91)
The value here represents minimum change in wattage (in
terms of wattage) for a REPORT to be sent (Valid values 0-
60000).
0x5C (92)
The value here represents minimum change in wattage
percent (in terms of percentage) for a REPORT to be sent
(Valid values 0-100).
0x65 (101)
Which reports need to send in Report group 1 (See flags in
table below).
0x66 (102)
Which reports need to send in Report group 2 (See flags in
table below).
0x67 (103)
Which reports need to send in Report group 3 (See flags in
table below).
Configuration Value n(LSB)
Default Value
Size
0
1
0
1
-
0
1
0
1
Value1=0x1B
3
Value2=0x1
Value3=0x1B
50
1
0
1
25 (W)
2
5 (%)
1
0x00 00 00 0
0x00 00 00 08
0