Sfoglia online o scarica il pdf Manuale di istruzioni per Interruttore Dinel Flexi Watch FLD-32. Dinel Flexi Watch FLD-32 16. Thru-wall level switch
Attachment bands are recommended for applications where frequent removal of the sensor
from the vessel surface is expected.
7 . E
lECTriCal CONNECTiON
The positive pole of the power supply (+U) is connected to the brown wire, the negative (0V)
to the white wire. The output from the sensor is fitted with short-circuit protection. Capacitive
loads and those with low resting resistance (light bulb) are evaluated by the sensor as a short-
circuit.
connecting the sensor with programming wire (version W)
connecting the sensor without programming wire (version M)
8 . S
ENSOr SETup
The setup is made by using green wire (so-called programming) at version FLD-32N-W-S or
by touching the magnetic pen MP-8 at version FLD-32N-M-S to the sensitive spot on the body
of the sensor. This can be used to setup the upper and lower limits of liquid level, SO modes
(open contact when the level decreases) and SC (closed contact when the level decreases).
© Dinel, s.r.o.
FLD-32
BN
GN
WH
BN
WH
Note: In case of strong envi-
ronmental electromagnetic
interference, routing of wires
next to high-voltage lines or
when the total distance is
more than 30 m, the use of
a shielded cable is recom-
mended.
Cable core
identification:
BN - brown
GN - green
WH - white
7