2. E
lECTriCal CONNECTiON
a) The type of sensor GPLS–25N–_-S
Positive pole (+U) of power supply is connected through a load (relay) to brown wire
or pin connector No. 1, negative pole is connected to while wire or pin connector No.3.
b) The type of sensor GPLS–25N–_-P
Positive pole (+U) of power supply is connected to brown wire or pin connector No.1,
negative pole is connected to blue wire or pin connector No.3. Load (relay) is connec-
ted to black wire or pin connector No.2.
Connection scheme of sensor with "PNP" type output
Legend:
(1)... – Terminals number for variants with connector
BN – Brown
Note:
The sensor output is protected againts short circuits. Capacity loads and loads with low sleep resistance (bulb) the
sensor evaluation as a short circuit. In case of high ambient electromagnetic interference, parallel conductors with
power lines, or lines at distances greater than 30 m, we recommend to use shielded cable.
Electrical connection must be done in de-energized state!
For switching supply sources, it is necessary to check that the input is galvanically
separated from the network side and that they are fitted with a filter suppressing the
conforming interference (terminals + and – oscillate together towards the ground
potential), or the interference is removed in another manner.
5
Connection scheme of sensor with "S" type output
WH – White
BU – Blue