Dinel ULM-53 series Manuale - Pagina 7

Sfoglia online o scarica il pdf Manuale per Livella laser Dinel ULM-53 series. Dinel ULM-53 series 8. Ultrasonic level meters
Anche per Dinel ULM-53 series: Manuale di istruzioni (20 pagine), Manuale di istruzioni (20 pagine), Manuale (6 pagine)

Dinel ULM-53 series Manuale

Range of application

Thanks to the proximity principle employed, the devices are suitable for continuous or limit measurement of the level of liquids,
waste water, sludge, suspensions, adhesives, resins in various open and closed vessels, sumps, open channels and drains.
Applicability for measuring the surface level of loose materials is limited, the range of measurement is shorter there.

Order code

ULM
53

Correct specification examples

ULM–53N–02–G–I–G–T
ULM–53Xi–06–G–I–B–M
Accessories
standard
(included in device price)
• 1x seal (for UL_–53_– 01; 02; 06, 10)
• 1x connector with IP67 coverage (for versions with
an ISO connector)
• 1x magnetic pen MP–8 (for device type adjusted
with a magnetic pen)
• free-to-download programme Basic Scada Level
(for the Modbus version)
Control units:
Connection method:
Output type: I – current output (4 ... 20 mA)
Process connection: G – pipe thread
Maximum range: 01 – 0,10 ... 1 m
Performance:
ULM–53N–20–F–U–H–M
ULM–53N–10–G–M–C–L
cable (cable length in m) – only for variants with connection type "B" and "H"
adjustable range (in dm) – only variants without setting controls "L"
T – setting using buttons
M – setting using a magnetic pen (MP8)
L – no setting controls and LED
G – ISO connector
C – M12 connector
B – short cable gland PG11
H – cable gland for protective hose
U – voltage output (0 ... 10 V)
M – RS-485 line with Modbus RTU communication
F – flange
02 – 0,20 ... 2 m
06 – 0,20 ... 6 m
10 – 0,4 ... 10 m
20 – 0,5 ... 20 m
N – non-explosive atmosphere
Xi – explosive atmosphere
optional
(for a extra charge)
• stainless steel or plastic fastening nuts G ¾", G1", G1 ½" and
G2 ¼
• stainless steel or plastic lugs G ¾", G1", G1 ½" and G2 ¼
• horn adapter ST–G1 (thread G1"), ST–G1,5 and ST–G2,25
• socket ELWIKA 4012 K PG7
• connector with IP67 coverage (type GAN-DADE 7A) with 5m
cable
(for current output and ISO type connector)
• connector with IP67 coverage (type GAN-DAEE 7A) with 5m
cable
(for voltage output and ISO type connector)
• converter URC-485 (for the Modbus version)
with output type "I" and "U":
0005 ... 0020 – 0,5 ... 2 m (variant „02")
0008 ... 0050 – 0,8 ... 5 m (variant „06")
0010 ... 0090 – 1,0 ... 9 m (variant „10")
0020 ... 0200 – 2,0 ... 20 m (variant „20")
ULM-53-dat-7.8