Ariston 47-166-32 Manuale d'uso, istruzioni per l'installazione e la manutenzione - Pagina 23
Sfoglia online o scarica il pdf Manuale d'uso, istruzioni per l'installazione e la manutenzione per Scaldabagno Ariston 47-166-32. Ariston 47-166-32 50.
Installation
6.14
E
/S
LECTRICAL
YSTEM
A
5
CN104
4
CN103
3
CN102
2
CN100
1
CN101
A
B
L
F
. 6.23
IG
A - Jumper:
1 -
Don't move (jumper is factory set in position B)
2 -
Anti-cycling Device Adjustment for Heating
Position A = 0 mins
3 -
Don't move (jumper is factory set in position B)
4 -
Don't move (jumper is factory set in position B)
5 -
Fan/Pump over-run selector
Position A = OFF
B - Central Heating Temperature Adjustment
C - Connector for Remote Control (Climate Manager)
D - Domestic Hot Water Temperature Adjustment
E - Soft-light Adjustment
F - Maximum Heating Adjustment
G - Time Clock Connector
H - On/Off Switch
I -
Fume Sensor L.E.D.
J -
Central Heating Selector
K - Ignition Failure (Lockout) L.E.D.
L - On/Off L.E.D.
M - Reset Button
N - Central Heating L.E.D.
O - Transformer
P - Spark Generator I.C.
Supplied By www.heating spares.co Tel. 0161 620 6677
D
IAGRAMS
J
K
M
N
Position B = 2 mins
Position B = ON
G
FUSE
FUSE
P
O
Q - Motorised diverter valve Relay
R - Gas Valve Relay
S - Circulation Pump Relay
T - Fan Relay
A01 - Circulation Pump
A02 - Fan
A03 - Spark Generator Supply
A04 - Gas Valve Supply
A05 - Motorised diverter Valve
A07 - Detection Electrode
A08 - Main Circuit Temperature Probe
A09 - Domestic Hot Water Temperature Probe
A10 - D.H.W. Flow switch
A11 - Pump Pressure Switch
A12 - Modulator
A13 - Air Pressure Switch
A14 - Safety Thermostat
A15 - External (Room) Thermostat
COLOURS:
Gr - Grey
Bi - White
Rs - Red
Mr - Brown
23
A
T
CN104
S
CN103
CN102
R
CN100
Q
CN101
A
Bl - Blue
Nr - Black
Ro - Pink
5
4
3
2
1
B