Aeotec TriSensor ZWA005 Manuale - Pagina 2
Sfoglia online o scarica il pdf Manuale per Accessories Aeotec TriSensor ZWA005. Aeotec TriSensor ZWA005 2.
8) Led Indicate Disable
Parameter Number
Size (Byte)
Available Settings
Default value
This parameter is configured the Led light on disable or enable.
5
1
0 ~ 3
3
'1' – Enable Led Blink when device detects a motion event.
'0' – Disable Led Blink. This configuration is not affect inclusion, exclusion and
6) Basic Set Value Settings for Group 2
reset.
'0' – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion
event is triggered, send BASIC_SET = 0x00 to devices associated in
Parameter Number
Size (Byte)
Available Settings
group 2 when motion event is cleared.
10
1
0 , 1
'1' – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion
event is triggered, send BASIC_SET = 0xFF to devices associated in
9) Led Color For Motion Event Report
group 2 when motion event is cleared.
'0' – Disable.
'2' – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion
'1' – Red.
event is triggered.
'2' – Green.
'3' – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion
'3' – Blue.
event is triggered.
'4' – Yellow.
'4' – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion
event is cleared. '5' – Send BASIC_SET = 0xFF to devices associated in
'5' – Pink.
'6' – Cyan.
Group 2 when motion event is cleared.
'7' – Purple.
Parameter Number
Size (Byte)
Available Settings
Default value
'8' – Orange.
6
1
0 ~ 5
0
Parameter Number
Size (Byte)
Available Settings
7) Temperature Alarm Value
11
1
0 ~ 8
This parameter is configured the threshold value that alarm level for
temperature. When the current ambient temperature value is larger than this
10) Led Color For Temperature Sensor Report
configuration value, device will send a BASIC_SET = 0xFF to nodes
'0' – Disable.
associated in group 3. If current temperature value is less than this value,
'1' – Red.
device will send a BASIC_SET = 0x00 to nodes associated in group 3.
'2' –Green.
Value = [Value] × 0.1(Celsius / Fahrenheit)
'3' – Blue.
'4' – Yellow.
Parameter Number
Size (Byte)
Available Settings
Default value
'5' – Pink.
'6' – Cyan.
EU/AU
2
-400 ~ 850 (Celsius)
239 (Celsius)
7
'7' – Purple.
US
2
-400 ~ 1185 (Fahrenheit)
750 (Fahrenheit)
'8' – Orange.
13) Led Color For Wakeup Notification Report
Parameter Number
Size (Byte)
Available Settings
Default value
'0' – Disable.
12
1
0 ~ 8
0
'1' – Red.
'2' –Green.
11) Led Color For Light Sensor Report
'3' – Blue.
'0' – Disable.
'4' – Yellow.
Default value
'1' – Red.
'5' – Pink.
'2' –Green.
1
'6' – Cyan.
'3' – Blue.
'7' – Purple.
'4' – Yellow.
'8' – Orange.
'5' – Pink.
'6' – Cyan.
Parameter Number
'7' – Purple.
15
'8' – Orange.
14) Temperature Scale Setting
Parameter Number
Size (Byte)
Available Settings
Default value
Configure temperature sensor scale type, Temperature to report in Celsius or
Fahrenheit.
13
1
0 ~ 8
0
0 – Celsius (C).
12) Led Color For Battery Report
1 – Fahrenheit (F).
'0' – Disable.
Parameter Number
Default value
'1' – Red.
'2' –Green.
EU/AU
2
20
US
'3' – Blue.
'4' – Yellow.
15) Temperature Threshold Value to Report
'5' – Pink.
Change threshold value for change in temperature to induce an automatic
'6' – Cyan.
report for temperature sensor. Scale is identical setting in Parameter No.20.
'7' – Purple.
Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on
'8' – Orange.
Parameter No.20) to induce automatic report or setting a value of 2 will be a
change of 0.2(C or F).
Parameter Number
Size (Byte)
Available Settings
Default value
14
1
0 ~ 8
0
Parameter Number
21
16) Light intensity Threshold Value to Report
Chang
Size (Byte)
Available Settings
Default value
22
2
0 ~ 10000
100
17) Temperature Sensor Report Interval
This parameter is configured the time interval for temperature sensor report.
This value is larger, the battery life is longer. And the temperature value
changed is not obvious. Unit: Second.
Parameter Number
Size (Byte)
Available Settings
Default value
Size (Byte)
Available Settings
Default value
23
2
1 ~ 32767
3600
1
0 ~ 8
0
18) Light Sensor Report Interval
This parameter is configured the time interval for light sensor report. This
value is larger, the battery life is longer. And the light intensity changed is not
obvious. Unit: Second.
Parameter Number
Size (Byte)
Available Settings
Default value
24
2
1 ~ 32767
3600
Size (Byte)
Available Settings
Default value
1
0 , 1
0
Temperature Offset Value
1
0 , 1
1
The current measuring temperature value can be add and minus a value by this
setting. The scale can be decided by Parameter Number 20.
Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit)
Parameter Number
Size (Byte)
Available Settings
Default value
30
2
-200 ~ 200
0
19) Light Intensity Offset Value
Size (Byte)
Available Settings
Default value
The current measuring light intensity value can be add and minus a value by
2
0 ~ 250
20
this setting.
*
COMMAND_CLASS_VERSION (V2)
Parameter Number
Size (Byte)
Available Settings
Default value
*
COMMAND_CLASS_POWERLEVEL (V1)
31
2
-1000 ~ 1000
0
*
COMMAND_CLASS_ASSOCIATION (V2)
*
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION (V3)
20) Light Sensor Calibrated Coefficient
*
COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
This configuration defines the calibrated scale for ambient light intensity.
*
COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
Because the method and position that the sensor mounted and the cover of
*
COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
sensor will bring measurement error, user can get more real light intensity by
*
COMMAND_CLASS_BATTERY (V1)
this parameter setting. User should run the steps as blows for calibrating
*
COMMAND_CLASS_WAKEUP (V2)
1) Set this parameter value to default (Assumes the sensor has been added
*
COMMAND_CLASS_NOTIFICATION (V8)
in a Z- Wave Network).
*
COMMAND_CLASS_SENSOR_BINARY (V2)
2) Place a digital luxmeter close to sensor and keep the same direction,
*
COMMAND_CLASS_SENSOR_MULTILEVEL (V7)
monitor the light intensity value (Vm) which report to controller and record
*
COMMAND_CLASS_CONFIGURATION (V1)
it. The same time user should record the value (Vs) of luxmeter.
*
COMMAND_CLASS_SUPERVISION (V1)
3) The scale calibration formula: k = Vm / Vs.
4) The value of k is then multiplied by 1024 and rounded to the nearest whole
number.
5) Set the value getting in 5) to this parameter, calibrate finished. For
example, Vm = 300, Vs = 2600, then k = 2600 / 300 = 8.6667 k = 8.6667 *
1024 = 8874.7 ≈ 8875
The parameter should be set to 8875.
Parameter Number
Size (Byte)
Available Settings
Default value
100
2
1 ~ 32767
1024
All Supports Command Class
This device supports Z-Wave Command Class as follows:
*
COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
*
COMMAND_CLASS_SECURITY (V1)
*
COMMAND_CLASS_SECURITY_2 (V1)
FCC ID: 2AOGIZWA005
*
COMMAND_CLASS_TRANSPORT_SERVICE (V2)
www.aeotec.com