Aeotec Water Sensor 7 Pro Manuale d'uso - Pagina 12
Sfoglia online o scarica il pdf Manuale d'uso per Accessories Aeotec Water Sensor 7 Pro. Aeotec Water Sensor 7 Pro 13. Water sensor
Anche per Aeotec Water Sensor 7 Pro: Manuale (3 pagine), Manuale di avvio rapido (8 pagine), Manuale d'uso (9 pagine), Manuale d'uso (14 pagine), Manuale d'uso (9 pagine)
4.9
Binary Sensor
Sensor Type
Water
0x06
Water
0x06
4.10 Multilevel Sensor
Sensor Type
Temperature
0x01
Relative Humidity
0x05
4.11 Wake Up
Parameter
Min Wake Up Interval Seconds
Max Wake Up Interval Seconds
Default Wake Up Interval Seconds
Wake Up Interval Step Seconds
4.12 Battery
1.
The 2.90V or more battery voltage corresponds to 100% battery level, and 2.60V or less corresponds to 0%.
2.
If send Battery Get to the device, it will issue Battery Report with battery level to the requester when waked up.
3.
If waked up or power on, it will detect battery level, and issue Battery Report via Lifeline when battery level change
over 10%.
4.
if the battery level is less then the value of configuration parameter 23, send Battery Report 0xFF and Notification
Report of replace battery now via Lifeline .
5.
If the battery level is less than the value of configuration parameter 23 , LED will flash red 3 times for each waked up.
4.13 Indicator
Indicator ID
Node Identify
(Green Led)
AEOTEC User Manual
Sensor Value
0xFF
0x00
Support Scale
Celcius (°C)
Fahrenheit (°F)
Percentage value (%)
Value
0x000E10
0xEFF100
0x093A80
0x0000F0
Property ID
0x50
On Off Period
On Off Cycles
On time within an On/Off period
Description
Water leakage Detected
Water leakage does not detect
Measure Range
-10 to 65°C (+- 1°C)
14 to 146°F (+- 1.8°F)
0 to 80% RH +- 3%
Page 9
Time
3600s [1 hour]
15724800s
604800s [1 week]
240s [4 minutes]
0x03
0x04
0x05