ERROR
NTC 1,2
This is not a safety error.
This condition shall be checked at power on, then every second or
any time the NFC is updated .
If EEPROM NFC data are not reliable (wrong eeprom nfc
checksum) the NFC DATA error shall be set.
NFC data
The machine shall be locked until data are recovered from NFC
internal memory. If NFC is not updated the error shall be
maintained until the next NFC update.
This is not a safety error.
If the control board cannot retrieve communication with the
TOUCH module the Touch Comm error shall be set.
Touch
This warning shall be shown to the user but the system shall not
comm
be locked. The condition shall be maintained until communication
is recovered.
This is not a safety error.
Wifi
If the control board cannot retrieve communication with the REM
comm
module the WiFi Comm error shall be set.This warning shall be
shown to the user but the system shall not be locked. The
condition shall be maintained until communication is recovered.
This is not a safety error.
If the control board cannot retrieve communication with the NFC
module (10 attempts) the NFC Comm error shall be set.
NFC
This condition shall be checked entering power supplied mode
comm
(from sleep or power on) or any time NFC is updated.
This warning shall be shown to the user but the system shall not
be locked. The condition shall be maintained until communication
is recovered.
PHENOMENON
9