Ariston 30 FF Manuale del prodotto - Pagina 29

Sfoglia online o scarica il pdf Manuale del prodotto per Caldaia Ariston 30 FF. Ariston 30 FF 48. Clas b

Ariston 30 FF Manuale del prodotto
4 MAIN FEATURES FOR THE TECHNICAL ASSISTANCE
SERVICE

4.1 SELF-DIAGNOSIS

To make it easier for the technical assistance service to identify the problem, the boiler is fitted with a state-
of-the-art self-diagnosis system, which shows the error code offering further information on the display.
The new error codification was thereby introduced; errors are no longer divided into type A and type E faults.
The main features of the new codification are as follows:
(D1) error codes are divided into six groups;
(D2+D3) indicating the group to which it belongs.
EXAMPLE :
Code 501: No flame
The boiler stores the last 10 errors in its memory (Operating Shutdown, Safety
Shutdown and Warning Signals), helping the technical assistance service during
maintenance work.
Standardisation on a component level has led to the unification of the main
components and a reduction in the number of spare part codes, thereby greatly
facilitating the various necessary maintenance activities.
COD
ERROR GROUPS
1 XY
Primary circuit
2 XY
Secondary circuit
3 XY
Internal electronics
4 XY
Peripherals (Clima Manager, ...)
5 XY
Flame circuit-Flue gas exhaust circuit
6 XY
Exhaust fume circuit

4.2 ERRORS IN THE MEMORY

4.3 REDUCTION OF SPARE PART CODES

Pag. 29 di 48