Ariston ACO 35 MFFI Manuale d'uso - Pagina 10

Sfoglia online o scarica il pdf Manuale d'uso per Caldaia Ariston ACO 35 MFFI. Ariston ACO 35 MFFI 12. Combi

Ariston ACO 35 MFFI Manuale d'uso
6
. DIGITAL PROGRAMMER
Manual switch
Reset
Enter
switching
times
Imput

time

Status
Enter
weekday/s
Operating the time switch
The steps marked with the symbol "
out a switching program.
Preparing for Operation
Activate the "Res" switch (=RESET) to reset the time switch
to its default setting (activate using a pencil or similar pointed
instrument). Do this:
- every time you wish to "reset" the time switch
- to erase all switching times and the current time of day.
After approximately two seconds the following display
appears:
Enter current time and weekday
- Keep the "
" key pressed down
During the summer time period press the +/- 1h key once.
Enter the hour using the "h" key
Enter the minutes using the "m" key
Enter the day using the "Day" key
1 = "Monday"..............7 = Sunday
- Release the "
" key.
Entering the switching times
You have 20 memory Iocations available. Each switching time
takes up one memory location.
Keep pressing the "Prog" key until a free memory location is
shown in the display "– –:– –".
Programme ON or OFF with the "
"
"= OFF; "
"= ON
Enter the hour using "h"
Enter the minutes using "m"
If a switching command is to be carried out every day (1 2 3
4 5 6 7) then store using the "
day(s) it is carried out by using the "Day" key.
When the day seIection is left bIank, the programmed switch-
ing instruction operates at the same time every day
1 2 3 4 5 6
= Monday – Saturday
1 2 3 4 5
= Monday – Friday
6 7
=Saturday – Sunday
10
Summer and
winter time
setting
Enter
the hours
Week-
days
flash
Enter
minutes
Day
" are necessary to carry
" key:
" key, otherwise select the
Selection of single days: 1 = Mon. .............. 2 =Tues.
Save the switching time with the "
The time switch enters the automatic operating mode and dis-
plays the current time of day.
Begin any further entry of a switching time with the "Prog"
switch. If your entry is incomplete, the segments not yet
selected will blink in the display. After programming is com-
pleted, and you return the time clock to the current time dis-
play with the "
" key, the time clock will not activate any
switching instruction required for the current time. You may
need to manually select the desired switching state with the
"
" key. Thereafter, as the unit encounters further switch-
ing instructions in the memory in real time, it will correctly acti-
vate all subsequent switching instructions.
Manual Override Switch "
With the "
" you can change the current setting at any time.
The switching program already entered is not altered.
Reading the programmed switching times
Pressing the "Prog" key displays the programmed switching times until
the first free memory location appears in the display "– – : – –".
If you now press the "Prog" key once again, the number of free
memory Iocations will be displayed, e.g. "18". If all memory loca-
tions are occupied, the display "00" appears.
Changing the programmed switching times
Press the "Prog" key repeatedly until the switching time you want
to change is displayed. You can now enter the new data. See
point "Entering the switching times".
Notes on storing switching times:
If you end your entry of the switching times by pressing the "Prog"
key, then the switching time you have entered will be stored and
the next memory location displayed.
In addition, a complete switching command is stored automati-
cally after around 90 seconds provided no other key is pressed.
The time switch then enters the automatic operating mode and
displays the current time again.
" key.
"